4. The control panel (type MTR-DCI-...-H2)
4-15
Festo P.BE-MTR-DCI-PB-EN en 1209a
[Position set]
Teach mode for programming the position set table
[Position set]
Param.
Description
[Position nr]
Nr
Number of the position set record
[0...31]
[Pos set mode]
[absolute/
relative]
Positioning mode
absolute = absolute position
specification, related to the pro-
ject zero point
relative = relative position
specification, related to the
current position
[Position]
xt
Target position in the selected
system of measurement
e.g. [mm]
[Velocity]
v
Positioning speed in the selected
system of measurement
e.g. [mm/s]
[Save...]
Save parameters in EEPROM
[PB parameter]
Sets the PROFIBUS address of the MTR-DCI-...-PB
[PB parameter]
Description
[PROFIBUSADR]
PROFIBUS address of the MTR-DCI-...-PB
Note
The parameters you have set take effect immediately upon
confirmation with OK <ENTER>.
•
Save the parameter settings permanently in EEPROM
with the
[Save] menu command. Only then will the set-
tings be retained even if the power supply is switched
off or if there is a power failure.