4. The control panel (type MTR-DCI-...-H2)

4-15

Festo P.BE-MTR-DCI-PB-EN en 1209a

[Position set]

Teach mode for programming the position set table

[Position set]

Param.

Description

[Position nr]

Nr

Number of the position set record
[0...31]

[Pos set mode]

[absolute/
relative]

Positioning mode
absolute = absolute position
specification, related to the pro-
ject zero point
relative = relative position
specification, related to the
current position

[Position]

xt

Target position in the selected
system of measurement
e.g. [mm]

[Velocity]

v

Positioning speed in the selected
system of measurement
e.g. [mm/s]

[Save...]

Save parameters in EEPROM

[PB parameter]

Sets the PROFIBUS address of the MTR-DCI-...-PB

[PB parameter]

Description

[PROFIBUSADR]

PROFIBUS address of the MTR-DCI-...-PB

Note
The parameters you have set take effect immediately upon
confirmation with OK <ENTER>.

Save the parameter settings permanently in EEPROM
with the

[Save] menu command. Only then will the set-

tings be retained even if the power supply is switched
off or if there is a power failure.