2 description of faults and warnings – Festo Электромотор MTR-DCI User Manual

Page 180

Advertising
background image

6. Diagnostics and fault display

6-8

Festo P.BE-MTR-DCI-PB-EN en 1209a

Cat-
egory

Status
bytes

2)

Fault
LED

Fault
number

Device
Error

1)

Description

Name, display

Fault

PLEASE ENFORCE
HOMING RUN!

Not referenced
(homing not carried
out)

0x0200

1

ON

FAULT

Warning

STANDSTILL-
WARNING

Standstill
monitoring

0x4000

36

FLASH-
ING

WARN,
STILL

Fault

PROFIBUS-INIT-
ERROR

Hardware
initialisation fault

0x8000

51

ON

FAULT

Warning

HOT TEMPERATURE

Temperature
too high

FLASH-
ING

WARN

Warning

COLD
TEMPERATURE

Temperature
too low

FLASH-
ING

WARN

1)

See object 2FF1/00

2)

For FHPP status bytes, see section 5.7.2

Tab. 6/7: Faults and warnings with fault numbers and fault bits

6.3.2

Description of faults and warnings

Messages

Messages give information regarding operating states.

Message

Cause

Attention!
Motor moves...

Message before the start of a positioning move-
ment. After confirmation with the <ENTER> button,
the drive starts moving.

Profile velocity
= 0. Please set
v.

The menu command [Move position set] is not
being executed because the positioning speed
of the position set record is v = 0. Modify the
parameter assignment or select a different
position set record.