Homing Velocities
PNU
1012
1...2
0...1
uint32
rw
Description
Speeds during homing
Search REF 1012
1
0
Speed when searching for the homing point (reference point) REF, in [inc/s]
Value range:
MTR-DCI-32: 200...33000
MTR-DCI-42: 200...50000
MTR-DCI-52: 200...50000
MTR-DCI-62: 200...56700
Default:
MTR-DCI-32: 27000
MTR-DCI-42: 22400
MTR-DCI-52/62: 16800
Search AZ 1012
2
1
Speed when moving to the axis zero point AZ, in [inc/s]
Value range:
MTR-DCI-32: 27000
MTR-DCI-42: 22400
MTR-DCI-52/62: 16800
CI access
6099h
01h...02h
uint32
rw
Homing Required
PNU
1014
–
–
uint8
ro
Description
Defines whether or not homing must be carried out after switching on in order
to carry out positioning tasks.
With MTR-DCI-PB, homing must always be carried out after switching on the
logic voltage supply.
Value:
0 (0x00): Reserved (no homing run necessary)
1 (0x01): Homing run must be carried out (fixed)
CI access
23F6h
00h
uint8