Festo Электромотор MTR-DCI User Manual

Page 46

Advertising
background image

2. Mounting

2-6

Festo P.BE-MTR-DCI-PB-EN en 1209a

L3

L3 x 0.5

F

y

F

x

Fig. 2/1:

Forces and torques

Forces and torques

32

42

52

62

MTR-DCI-...-G7 1-stage

Radial shaft load

Axial shaft load

Maximum safe shaft output torque for the
gear

1)

F

y

[N]

F

x

[N]

Mx [Nm]

40
10
0.4

160
50
0.8

200
60
2.0

240
50
4

MTR-DCI-...-G14/G22 2-stage

Radial shaft load

Axial shaft load

Maximum safe shaft output torque for the
gear

1)

F

y

[N]

F

x

[N]

M

x

[Nm]

70
20
1.0

230
80
7.5

320
100
12.0

360
70
25

2)

1)

With operating factor cb=1.0 (3 hours operation daily, no shocks, direction of rotation constant).
The gear output torque or the motor unit is usually much lower, see Technical appendix A, Mech-
anical data.

2)

MTR-DCI-62...-G22: In the start-up phase, torque peaks up to 37 Nm are possible at 20 A peak
current.

Tab. 2/2: Safe load for the gear shaft

Advertising