Festo Электромотор MTR-DCI User Manual
Page 283

B. Supplementary information
B-77
Festo P.BE-MTR-DCI-PB-EN en 1209a
Password (FCT password)
Super Password 20FAh
02h
V-string
w
For entering the super password.
Resets all passwords (FCT password and HMI password, object 20FB). Contact
Festo Service if you require the super password.
Local Password
CI access
20FBh
00h
Var
V-string
rw
Description
For managing the (local) HMI password to enable particular functions which are
carried out via the control panel.
Value:
<........> (fixed: 8 characters, ASCII, 7-bit)
Only the first 3 characters are evaluated.
Default:
<
00000000> (status upon delivery and after reset)
Communication Error (transmission error)
CI access
2FF0h
00h
Var
uint16
r
Description
Special object; see section B.2.2.
In the event of a transmission error, the value <0x00FF> will be transferred in-
stead of the usual response.
PROFIBUS Address
CI access
2FF3h
00h
Var
uint8
rw
Description
PROFIBUS address of the MTR-DCI.
Values:
0 ... 125 (0x00 ... 0x7D)
Default:
255 (0xFF, invalid address)