Commissioning 5-61 – Festo Электромотор MTR-DCI User Manual

Page 149

Advertising
background image

5. Commissioning

5-61

Festo P.BE-MTR-DCI-PB-EN en 1209a

Step/
Description

Status bytes

Control bytes

Step/
Description

B0

B1

B2

B3

B4

B5

B6

B7

Byte

B0

B1

B2

B3

B4

B5

B6

B7

Byte

7.6 Positioning task
interrupted (stroke
limit or software end
position reached)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON 0

1

x

x

0

x

1

1

SCON 0

1

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

x

1

SPOS 1

0

0

0

0

1

x

1

Byte 3

FUNC

FAST

XUM

CONT COM2 COM1

ABS

Byte 3

FUNC

FAST

XUM

VUM

CONT COM2 COM1

ABS

CDIR

0

0

S

x

0

0

1

0

SDIR

0

0

1

0

0

0

0

0

7.7 End positioning
task (e.g. with STOP)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON 0

1

x

x

0

x

0

1

SCON 0

1

0

1

0

0

0

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

x

1

SPOS 1

0

0

0

0

1

x

1

Byte 3

FUNC

FAST

XUM

CONT COM2 COM1

ABS

Byte 3

FUNC

FAST

XUM

VUM

CONT COM2 COM1

ABS

CDIR

0

0

S

x

0

0

1

0

SDIR

0

0

0

0

0

0

0

0

0: 0-signal;

1: 1-signal;

x: not relevant (any);

F: Edge positive

S: Path limitation (stroke limit): 0 = stroke limit active, 1 = stroke limit not active

Tab. 5/15: Control and status bytes for “Direct mode – Force mode”

Description for Force mode:

Once “ready to operate” is established and homing has been
carried out, a nominal value must be specified and the sys-
tem must be prepared for operation in Force mode.

7.1

Specify the nominal value in % of nominal motor cur-
rent.

7.2

Prepare Force mode: set bit CDIR.B1 COM1, and set bit
CDIR.B5 XLIM depending on the desired level of stroke
limitation.

7.3

Start the job with CPOS.B1 START. The start is con-
firmed with SPOS.B1 (acknowledge start) as long as
CPOS.B1 (START) is set.

Advertising