Controller parameters – Festo Электромотор MTR-DCI User Manual

Page 254

Advertising
background image

B. Supplementary information

B-48

Festo P.BE-MTR-DCI-PB-EN en 1209a

Controller parameters

Halt Option Code

PNU

1020

uint16

ro

Description

Describes the reaction to a Halt command.
Fixed = 1: braking with Halt ramp

CI access

605Dh

00h

uint16

ro

Fault Reaction Option Code

PNU

1021

uint16

ro

Description

Describes the reaction to a fault.
Fixed = 2: braking with emergency stop ramp

CI access

605Eh

00h

uint16

ro

Target Position Window

PNU

1022

uint32

rw

Description

Tolerance window in increments [inc]
Amount by which the current position may deviate from the target position and
still be regarded as being within the target window. The width of the window is
twice the value transferred, with the target position in the centre of the window.
Value range: 0 ... +(2

32

-1). Default: 750 (0x2EE)

CI access

6067h

00h

uint32

rw

Position Window Time (adjustment time for position)

PNU

1023

uint16

rw

Description

Adjustment time in milliseconds [ms].
Once the actual position has been in the target position window this amount of
time, the bit “target reached” will be set in the status word (= motion complete).
Value range: 1 ... 30000 (0x7530)
Default: 100 (0x64).

CI access

6068h

00h

uint16

rw

Advertising