B. Supplementary information

B-81

Festo P.BE-MTR-DCI-PB-EN en 1209a

Bit

Value

Description

0

0x0001

Ready to switch on

Bits 0 ... 3, 5 and 6 show the status of the device
(x ... irrelevant for this status)
Value (binary)

Status

xxxx xxxx x0xx 0000 Not ready to switch on
xxxx xxxx x1xx 0000 Switch on disabled
xxxx xxxx x01x 0001 Ready to switch on
xxxx xxxx x01x 0011 Switched on
xxxx xxxx x01x 0111 Operation enabled
xxxx xxxx x00x 0111 Quick stop active
xxxx xxxx x0xx 1111 Fault reaction active
xxxx xxxx x0xx 1000 Fault

1

0x0002

Switched on

2

0x0004

Operation enabled

3

0x0008

Fault

4

0x0010

Voltage enabled

5

0x0020

Quick stop

6

0x0040

Switch on disabled

7

0x0080

Warning (simple fault which does not require an emergency stop)

8

0x0100

Drive moves (corresponds to bit 4 of SPOS in FHPP)

9

0x0200

Master controller (corresponds to bit 5 of SCON in FHPP)

10

0x0400

Target reached (see also objects 6067 and 6068)

11

0x0800

Internal limit active

12

0x1000

Depends on operation mode (object 6060):

Profile Position mode: Setpoint_acknowledge

Homing mode: Homing_attained

Profile Torque Mode: is running

13

0x2000

Depends on operation mode (object 6060):

Profile Position mode: Following_error (position lag error)

Homing mode: Homing_error

Profile Torque Mode: stroke limit reached

14

0x4000

Manufacturer specific: Teach acknowledge
(corresponds to bit 3 of SPOS in FHPP)

15

0x8000

Manufacturer specific: referencing performed
(corresponds to bit 7 of SPOS in FHPP)

Tab. B/18: Description of Status Word