B. Supplementary information

B-28

Festo P.BE-MTR-DCI-PB-EN en 1209a

PROFIBUS Diagnosis

PNU

206

1...6

0...5

uint8

ro

Description

Reading the PROFIBUS diagnostic data

Connection State 206

1

0

Current connection state
0 (0x00): Waiting for parameter assignment
16 (0x10): Waiting for configuration
32 (0x20): Data exchange

Bit rate 206

2

1

Current bit rate
0 (0x00): 12 MBit/s

6 (0x06): 93.75 kBit/s

1 (0x01): 6 MBit/s

7 (0x07): 45.45 kBit/s

2 (0x02): 3 MBit/s

8 (0x08): 19.2 kBit/s

3 (0x03): 1.5 MBit/s

9 (0x09): 9.6 kBit/s

4 (0x04): 500 MBit/s

15, 255 (0x0F, 0xFF):

No bit rate (default),

5 (0x05): 187.5 kBit/s

Bit rate search active

Master Address 206

3

2

Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)

Slave Address 206

4

3

Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)

Configuration 206

5

4

Current configuration
0 (0x00): Invalid configuration
1 (0x01): Festo FHPP standard (8 bytes I/O)
2 (0x02): Festo FHPP standard + FPC (2 x 8 bytes I/O)

Settings

(connection set-

tings)

206

6

5

0 (0x00): Device-related diagnosis ON (default)
1 (0x01): Device-related diagnosis OFF

CI access

2FF2h

01h...06h

uint8

ro