Start/stop record – Festo Электромотор MTR-DCI User Manual

Page 159

Advertising
background image

5. Commissioning

5-71

Festo P.BE-MTR-DCI-PB-EN en 1209a

Start/stop record

Nominal record
number in output
data

Stop
CCON.B1 (STOP)

Acknowledge start
SPOS.B1 (ACK)

Motion Complete
SPOS.B2 (MC)

Actual record
number in
input data

N - 1

N

N + 1

N - 1

N

1

0

1

0

1

0

1

0

1

0

1

2

3

4

6

1

0

1

0

Axis is moving
SPOS.B4 (MOV)

Start
CPOS.B1 (START)

N + 1

5

1

Requirement:
“Acknowledge Start” = 0

2

Rising edge on “Start” causes the new
record number N to be accepted and
“Acknowledge Start” to be set.

3

As soon as “Acknowledge Start” is
detected by the PLC, it can set “Start”
back to 0.

4

The controller reacts with a falling
edge on “Acknowledge Start”.

5

As soon as “Acknowledge start” is
detected by the PLC, it can apply the
next record number.

6

A currently running positioning task
can be stopped with “Stop”.

Fig. 5/7:

Flow diagram for “start/stop record”