4 serial interface – Festo Электромотор MTR-DCI User Manual
Page 59
![background image](/manuals/464458/59/background.png)
3. Installation
3-11
Festo P.BE-MTR-DCI-PB-EN en 1209a
3.4
Serial interface
Serial interface for parameter assignment, commissioning
and diagnosis
In order to connect a PC to the MTR-DCI, use exclusively the
following cable:
– Programming cable KDI-MC-M8-SUB-9-2,5
1. If necessary, remove the protective cap from the serial
interface of the MTR-DCI.
2. Connect the following terminals using the programming
cable:
–
The connection socket on the MTR-DCI
–
A serial interface COMx on the diagnostic PC
M8x1 socket
Description
1
2
4
3
1
GND
Ground
2
TXD
RS232 transmitting cable
1)
3
RXD
RS232 receiving cable
1)
4
---
Reserved for service staff – do not
connect!
1)
The levels correspond to the RS232 standard and enable a data
transmission rate of 9600 bit/s
Tab. 3/5: Pin allocation for the serial interface on the MTR-
DCI