2 prefixes and directions – Festo Электромотор MTR-DCI User Manual

Page 33

Advertising
background image

1. System overview

1-13

Festo P.BE-MTR-DCI-PB-EN en 1209a

Point of reference

Calculation rule

Axis zero point

AZ

= REF

+ a

Project zero point

PZ

= AZ

+ d

= (REF

+ a) + d

Lower software end posi-
tion

LSE

= AZ

+ b

= (REF

+ a) + b

Upper software end posi-
tion

USE

= AZ

+ c

= (REF

+ a) + c

Tab. 1/2: Calculation rules for the measuring reference sys-

tem with incremental measuring systems

1.5.2

Prefixes and directions

All offsets and position values are vectors (with prefix). The
+/- active direction of the vectors can be assigned to the dir-
ection of rotation of the motor shaft (view on the motor
shaft). The factory setting for a clockwise direction of rotation
is “+”; for an anti-clockwise direction of rotation, “-”. The
assignment can be reversed on the control panel (see chapter
4.4) or via the FCT. This can be advantageous when using
right-angle or toothed belt gearboxes. A new reference travel
is required after a reversal of direction.

The direction in which the effective load moves is dependent
on the gear unit, the spindle type (clockwise/anti-clockwise
rotation), the prefix for the position specifications (+/-) and
the active direction set:

Advertising