B. Supplementary information

B-52

Festo P.BE-MTR-DCI-PB-EN en 1209a

Drive data (drive data)

CI

6510h

01h...

Record

ro/rw

Drive data

1)

6510h

01h...08h

uint32

rw

6510h

31h, 32h,
40h, 41h
42h, 43h,
A0h, 22h

uint16, uint16,
uint32, uint16,
int16, uint16,
uint32, uint32

ro, ro
ro, ro
ro, rw
ro, ro

Current actual

value (current

actual value)

6510

45h

int 16

ro

Current actual value of the current.
Note: Not available via FHPP.

Firmware design

(firmware number)

6510

A1h

uint32

ro

Firmware version, specification in BCD (binary coded decimal): xxyy
(xx = main version, yy = secondary version)
Note: Identical to FHPP object PNU 101 (CI 206A)

1)

Description similar to FHPP 1026/1...8

Electronic rating plate

Motor Type

PNU

1030

uint16

ro

Description

Classification of the motor. Fixed: 0x0000.

CI access

6402h

00h

uint16

ro

Max. Current

PNU

1034

uint16

rw

Description

Maximum motor current for homing in 1/1000 of the specified nominal current
(see also PNU 1035).
Note: keep in mind that the current limitation also limits the maximum possible
speed (or force) and that higher nominal speeds may not therefore be
achieved.
Value range: 1 ... 2000 (0x0001 ... 0x07D0)
Default: 1500 (0x05DC)

CI access

6073h

00h

uint16

rw

Advertising