Electronic rating plate – Festo Электромотор MTR-DCI User Manual

Page 258

Advertising
background image

B. Supplementary information

B-52

Festo P.BE-MTR-DCI-PB-EN en 1209a

Drive data (drive data)

CI

6510h

01h...

Record

ro/rw

Drive data

1)

6510h

01h...08h

–

uint32

rw

6510h

31h, 32h,
40h, 41h
42h, 43h,
A0h, 22h

–

uint16, uint16,
uint32, uint16,
int16, uint16,
uint32, uint32

ro, ro
ro, ro
ro, rw
ro, ro

Current actual

value (current

actual value)

6510

45h

int 16

ro

Current actual value of the current.
Note: Not available via FHPP.

Firmware design

(firmware number)

6510

A1h

–

uint32

ro

Firmware version, specification in BCD (binary coded decimal): xxyy
(xx = main version, yy = secondary version)
Note: Identical to FHPP object PNU 101 (CI 206A)

1)

Description similar to FHPP 1026/1...8

Electronic rating plate

Motor Type

PNU

1030

–

–

uint16

ro

Description

Classification of the motor. Fixed: 0x0000.

CI access

6402h

00h

uint16

ro

Max. Current

PNU

1034

–

–

uint16

rw

Description

Maximum motor current for homing in 1/1000 of the specified nominal current
(see also PNU 1035).
Note: keep in mind that the current limitation also limits the maximum possible
speed (or force) and that higher nominal speeds may not therefore be
achieved.
Value range: 1 ... 2000 (0x0001 ... 0x07D0)
Default: 1500 (0x05DC)

CI access

6073h

00h

uint16

rw

Advertising