Objects of the standstill monitoring – Festo Контроллеры двигателя SFC-LAC User Manual

Page 313

Advertising
background image

B. Parametrising as per FHPP−FPC

B−85

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Objects of the standstill monitoring

Position demand value

PNU

1040

ć

int32

r

Description

Controller setpoint position in [increments]

CI / DS402

6062h

00h

int32

r

Position actual value

PNU

1041

ć

int32

r

Description

Current position of the drive in [increments]

CI / DS402

6064h

00h

int32

r

Standstill position window

PNU

1042

ć

uint32

rw

Description

Standstill position window in [increments]: Amount by which the drive may
move after Motion complete", until the standstill monitoring responds.

CI / DS402

2040h

00h

uint32

rw

Standstill timeout

PNU

1043

ć

uint16

rw

Description

Standstill monitoring time in [ms}: Time during which the drive must be outside
the standstill position window before the standstill monitoring responds.
Value range: 0...65535 (0xFFFF). Default: 80

CI / DS402

2041h

00h

uint16

rw