1 specifications of the outputs, Specifications of the outputs – Festo Контроллеры двигателя SFC-LAC User Manual

Page 81

Advertising
background image

3. Installation

3−29

Festo GDCP−SFC−LACI−CO−EN en 0812NH

3.9.1

Specifications of the outputs

The local digital outputs are supplied by the 24 V logic
voltage (no electrical isolation). They are ESD−protected
and short circuit proof, but do not have reverse polarity
protection against infeed.

Caution
If 24 VDC voltage is applied and the output pins are used
incorrectly, the device may be seriously damaged. ThereĆ
fore:

·

Do not apply voltage to the outputs.

·

Note the current limitation for the outputs (max. 1 A
permissible per output).

Special features of output 1 (Out1)

ć

Standard PLC output (active high−side switching)

Special features of output 2 (Out2)

ć

Differential output (can be pulse−width modulated)

ć

High and low−side switching (active full bridge)

ć

It is not used for controlling a PLC, but rather for controlĆ
ling a load, e.g. to control a pulsed motor brake, a valve
or a fan.

The possible uses dependent on the selected pins are
described in section 5.6.10.