Parameters involved (record selection) – Festo Контроллеры двигателя SFC-LAC User Manual
Page 174
![background image](/manuals/464473/174/background.png)
5. Commissioning
5−72
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Parameters involved (record selection)
The entries in the positioning table can be written via the
fieldbus (PNU 401...417).
The composition of the positioning table as per FHPP is
described in appendix B.3.7. Record chaining is described
in section 5.6.5.
Overview of parameters involved (see section B.3.7)
Parameters involved
Description
FCT
PNU
CI
Mode (absolute/relative/energy optimised)
x
401
20E0/01h
Target position
x
404
20E0/02h
Speed
x
406
20E0/03h
Acceleration
x
407
20E0/04h
Deceleration (= Braking)
x
408
20E0/0Ah
Acceleration jerk
x
409
20E0/05h
Mass of the workpieces (without tool mass)
x
410
20E0/06h
Damping time
x
415
20E6h
20E0/07h
Deceleration jerk
x
417
20E0/0Bh
Start (FHPP)
CPOS.B1 = positive edge: Start
Jogging and referencing have priority.
Feedback (FHPP)
SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Acknowledge start
SPOS.B4 = 1: Drive moving
Requirements
Device control by PLC/fieldbus.
Controller must be in status Operation enabled".
Record number must be valid
Tab. 5/16: Parameters involved in Record Select mode