6. Diagnostics and error display

6−8

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Warnings

Warnings have no influence on the behaviour of the drive.
The cause of the warning should be eliminated in order that it
does not lead to a fault.

If a warning occurs, the fault LED will flash and the SCON.B2
WARN output will be set (FHPP status bits, see 5.5.2).

Warning

Cause

PNU 215

Fault
no.

*)

INDEX PULSE
WARNING

During homing: The homing switch signal lies too close
to the index pulse. In some cases Ăthis can mean that no
reproducible reference position can be determined.

·

See section 6.7.

0x0001

84

WARNING
MOTOR COLD

Temperature of the linear motor <Ă−10 °C. Increase
ambient temperature if necessary.

0x0002

108

WARNING
MOTOR HOT

Temperature of the linear motor 70...75 °C, check for
possible overloading of the drive; check the mechanical
system, e.g. for sluggishness; reduce ambient
temperature.

0x0004

109

WARNING
SFC−LACI COLD

Temperature <āāĂ−10

0x0008

74

WARNING
SFC−LACI HOT

Temperature 80...85 °C

0x0010

75

STANDSTILL
WARNING

The axis has moved outside the standstill tolerance
window.

0x0020

36

ILLEGAL
RECORD
WARNING

Non−permitted record number.

0x0040

3

*) Fault number in the diagnostic memory, see section 6.4.