Festo Контроллеры двигателя SFC-LAC User Manual

Page 325

Advertising
background image

B. Parametrising as per FHPP−FPC

B−97

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Limit switch deceleration

PNU

1304

ć

ć

int32

rw

Description

Limit switch deceleration: decelerating in [m/s

2

] with limit switch signal

CI / DS402

6510h

15h

int32

rw

Sample input

PNU

1305

ć

ć

uint32

rw

Description

Input for on−the−fly measurement (position sampling)
Value = 1: sampling at IN1; value = 2: sampling at IN2. See 5.6.12.

CI / DS402

6510h

16h

uint32

rw

Limit switch polarity

PNU

1306

ć

ć

uint8

rw

Description

Type of proximity switch used for position sampling.
0 = N/C contact, 1 = N/O contact

CI / DS402

6510h

1Ch

uint8

rw

Brake delay time switch ON

PNU

1310

ć

ć

uint16

rw

Description

Brake: switch on delay, see section 5.6.11

CI / DS402

6510h

17h

uint16

rw

Brake delay time switch OFF

PNU

1311

ć

ć

uint16

rw

Description

Brake: switch−off delay, see section 5.6.11

CI / DS402

6510h

18h

uint16

rw

Advertising