C. Object directory DS402 and CI

C−27

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Transmit PDO 1 mapping parameter

DS402

1A00h

01h...05h

Record

uint32

r

Description

Mapping parameters of PDO 1 which the device can transmit. No dynamic mapĆ
ping possible. The specified mapping depends on the selected device profile.

PDO mapping 1A00h

01h...05h

PDO mapping for the n−th mapped application object, depending on the seĆ
lected data/device profile:
Subindex

FHPP

DS 402

01h

Fixed: 0x30200008 Fixed: 0x60410010

02h

Fixed: 0x30210008 Fixed: 0x20320108

03h

Fixed: 0x30220008 Fixed: 0x60610008

04h

Fixed: 0x30230008 Fixed: 0x60640020

05h

Fixed: 0x30240020

Transmit PDO 2 mapping parameter

DS402

1A01h

01h...04h

Record

uint32

r

Description

Mapping parameters of PDO 2 which the device can transmit. No dynamic mapĆ
ping possible. The specified mapping depends on the selected device profile.

PDO mapping 1A01h

01h...04h

PDO mapping for the n−th mapped application object, depending on the seĆ
lected data/device profile:
Subindex

FHPP

DS 402 (not used)

01h

Fixed: 0x30300008 Fixed: 0x60410010

02h

Fixed: 0x30310008 Fixed: 0x20320108

03h

Fixed: 0x30320010 Fixed: 0x60610008

04h

Fixed: 0x30330020 Fixed: 0x60640020