5. Commissioning

5−33

Festo GDCP−SFC−LACI−CO−EN en 0812NH

PDO mapping in FHPP

The first PDO (8 bytes I/O data) is intended for the operating
modes Record Select and Direct Mode, the second PDO
(8 bytes I/O data) is used for FPC (Festo Parameter Channel)
parameterisation.

Receive PDO 1 (FHPP standard)

Operation
mode

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Record selecĆ
tion

CCON

CPOS

Record
No.

Reserved

Reserved

Direct mode

CDIR

Setpoint
value 1

Setpoint value 2

Receive PDO 2 (FHPP−FPC)

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

ParameterisaĆ
tion

Reserved

Sub−index Task identifier +

parameter number

Parameter value

Transmit PDO 1 (FHPP standard)

Operation
mode

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Record selecĆ
tion

SCON

SPOS

Record
No.

RSB

Actual position

Direct mode

SDIR

Actual
value 1

Transmit PDO 2 (FHPP−FPC)

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

ParameterisaĆ
tion

Reserved

Sub−index Task identifier +

parameter number

Parameter value