1 [settings] [axis type, 2 [settings] [axis parameters, Settings] [axis type – Festo Контроллеры двигателя SFC-LAC User Manual
Page 96: Settings] [axis parameters
4. The control panel (only type SFC−LACI−...−H2−...)
4−14
Festo GDCP−SFC−LACI−CO−EN en 0812NH
4.5.1
[Settings] [Axis type]
The connected drive is automatically detected.
4.5.2
[Settings] [Axis parameters]
Teach mode for setting the axis parameters
·
Observe the instructions in sections 5.2.5 and 5.2.6.
[Axis parameter] Description
[Zero point]
*)
Offset axis zero point
[SW−limit−neg]
*)
Software end position, negative
[SW−limit−pos]
*)
Software end position, positive
[Tool load]
Tool mass, e.g.Ăa gripper on the front plate/
piston rod
[SAVE...]
Save parameters in EEPROM
*)
Teaching is only possible after a successful homing run.
Note
A new homing run must always be carried out after modifyĆ
ing the axis zero point.
The project zero point PZ can only be set via FCT or PNUĂ500/
CIĂ21F4
h
.