Create readiness to operate ć record select, Commissioning 5−50 – Festo Контроллеры двигателя SFC-LAC User Manual

Page 152

Advertising
background image

5. Commissioning

5−50

Festo GDCP−SFC−LACI−CO−EN en 0812NH

1.Create readiness to operate ć Record select

Step/
D

i ti

Control bytes

Status bytes

Description

Byte

B7

B6

B5

B4

B3

B2

B1

B0

Byte

B7 B6 B5 B4 B3

B2 B1

B0

1.1 Basic status

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

1.1 Basic status

(device control

CCON 0

0

0

0

0

0

0

0

SCON 0

0

0

1

0

0

0

0

(device control
HMI = off )

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

HMI = off )

CPOS x

0

0

0

0

0

0

0

SPOS 0

0

0

0

0

1

0

0

1.2 Disable device

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

1.2 Disable device
control by FCT/HMI
(optional)

CCON x

x

1

x

x

0

x

x

SCON x

x

0

x

x

x

x

x

(optional)

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

CPOS x

x

x

x

x

x

x

x

SPOS x

x

x

x

x

x

x

x

1.3 Enable drive,

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

1.3 Enable drive,
enable operation

CCON

0

0

x

x

0

0

1

1

SCON

0

0

0

1

0

0

1

1

(record selection)

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

(record selection)

CPOS x

0

0

0

0

0

0

1

SPOS 0

0

0

0

0

1

0

1

0: Logic 0;

1: Logic 1;

x: not relevant (optional);

F: Edge positive

Tab. 5/4: Control and status bytes Creating readiness to operate ć Record selection"

Description of 1. Create readiness to operate:

1.1

Basic status of the drive when the supply voltage has
been switched on.
} Step 1.2 or 1.3

1.2

Optionally: Disable device control via FCT/HMI using
CCON.B5 = 1 (LOCK).

} Step 1.3

1.3

Enable drive in Record Select mode.
} Homing: Example 4, Tab. 5/7.

If there are faults after switching on or after setting CCON.B0
(ENABLE):
} Fault handling: see example 3, Tab. 5/6 and chapter 6.3
Error messages".