C.3 object descriptions, Object descriptions, C−19 – Festo Контроллеры двигателя SFC-LAC User Manual
Page 345: Ndix c.3
C. Object directory DS402 and CI
C−19
Festo GDCP−SFC−LACI−CO−EN en 0812NH
C.3
Object descriptions
Representation of DS402 and CI objects
Password
DS402 / CI
20FAh
01h...02h Array
V−string
rw/r
Description
Managing the FCT password, entering the super password.
FCT password
20FAh
01h
V−string
Password for the FCT software
Value:
<........> (fixed 8 characters, ASCII, 7−bit)
Default: <00000000> (status upon delivery and after resetting)
Super password
20FAh
02h
V−string
Entering the super password.
Resets all passwords (FCT password and HMI password, object 20FB).
Contact Festo Service if you require the super password.
1
Name of the parameter
2
Object number
3
Subindices of the parameter
4
Class of the element
5
Type of the element
6
Description of the parameter
7
If applicable: description of the
subindices
8
Read/write permission:
r = read only,
w = write only,
rw = read and write
Fig. C/1:
Representation of DS402 and CI objects
1
2
3
4
5
6
7
8