Festo Контроллеры двигателя SFC-LAC User Manual

Page 315

Advertising
background image

B. Parametrising as per FHPP−FPC

B−87

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Measurement system pitch

PNU

1052

ć

uint32

r

Description

Measurement graduation: distance [

ìm] between two index pulses

CI / DS402

6410h

13h

uint32

r

Nominal power

PNU

1053

ć

uint32

r

Description

Nominal power of the linear motor in [W]

CI / DS402

6410h

14h

uint32

r

Actual power

PNU

1054

ć

uint32

r

Description

Actual power of the linear motor in [W]

CI / DS402

6410h

15h

uint32

r

Offset reference point

PNU

1055

ć

int32

rw

Description

Distance in increments from the reference point to the retracted end position.
Must be stated when homing to a stop. See Tab. 1/3.

CI / DS402

6410h

16h

int32

rw

Advertising