Festo Контроллеры двигателя SFC-LAC User Manual
Page 317
B. Parametrising as per FHPP−FPC
B−89
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Actual coil temperature (temperature of the linear motor coils)
PNU
1060
ć
int16
r
Description
Measuring range: −20...+120 °C
CI / DS402
6410h
31h
int16
r
Max. coil temp
PNU
1061
ć
int16
r
Description
Highest coil temperature measured to date (= motor). Is saved in EEPROM.
Measuring range: −20...+120 °C.
CI / DS402
6410h
32h
int16
r
Lower coil temp threshold
PNU
1062
ć
uint16
rw
Description
Lower temperature threshold of the coils (= motor): 70 °C.
A warning is triggered when this temperature is reached.
CI / DS402
6410h
33h
uint16
rw
Upper coil temp threshold
PNU
1063
ć
uint16
rw
Description
Upper temperature threshold of the coils (= motor): 75 °C
An error message is triggered when this temperature is reached.
Restart only after the temperature has dropped below the lower threshold
(see PNU 1062).
CI / DS402
6410h
34h
uint16
rw