5. Commissioning

5−5

Festo GDCP−SFC−LACI−CO−EN en 0812NH

5.1.1

Checking the drive

Note
During operation, the drive must not strike a stop without
shock absorption.

·

Use shock absorbers or buffers on all stops (exception:
homing to a fixed stop).

·

Before commissioning, make sure that drive and conĆ
troller are completely set up and wired and that the workĆ
ing space is adequate for operation with an effective load.

·

Observe the notes in the operating instructions for the
axis used.

5.1.2

Checking the power supply

Caution
Interruption of running tasks due to inadequate load voltĆ
age supply (LOAD POWER DOWN")

·

Make sure that the load voltage supply tolerance can be
maintained at full load directly on the voltage terminal of
the SFC−LACI (see chapter 3.2).

Caution
Loss of reference position due to inadequate logic voltage
supply

·

Always carry out homing every time the logic voltage
supply is switched on or if a power failure has occurred,
in order to anchor the measuring reference system to
the reference point (REF).

The SFC−LACI does not carry out any positioning tasks if it
is not referenced.