5. Commissioning

5−54

Festo GDCP−SFC−LACI−CO−EN en 0812NH

4. Homing (requires status 1.4 or 1.5)

Step/Description

Control bytes

Status bytes

Byte

B7

B6

B5

B4

B3

B2

B1

B0

Byte

B7 B6 B5 B4 B3

B2 B1

B0

4.1 Start homing

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

4.1 Start homing

CCON 0

x

x

x

0

0

1

1

SCON 0

x

0

1

0

0

1

1

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

F

0

1

SPOS 0

0

0

0

0

0

1

1

4.2 Homing running

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

4.2 Homing running

CCON 0

x

x

x

0

0

1

1

SCON 0

x

0

1

0

0

1

1

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

1

0

1

SPOS 0

0

0

1

0

0

1

1

4.3 Homing finished

Byte 1

OPM2

OPM1

LOCK

ć

RESET BRAKE

STOP

ENABL

Byte 1

OPM2 OPM1

HMI

24VL

FAULT WARN

OPEN ENABL

4.3 Homing finished

CCON 0

x

x

x

0

0

1

1

SCON 0

x

0

1

0

0

1

1

Byte 2

ć

CLEAR TEACH

JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV

TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

0

1

SPOS

1

0

0

0

0

1

0

1

0: Logic 0;

1: Logic 1;

x: not relevant (optional);

F: Edge positive

Tab. 5/7: Control and status bytes Homing"

Description to 4. Homing:

4.1

A positive edge at CPOS.B2 HOM starts homing. The
start is confirmed with SPOS.B1 ACK (Acknowledge
start) as long as CPOS.B2 HOM is set.

4.2

Movement of the axis is shown with SPOS.B4 MOV.

4.3

After successful homing, SPOS.B2 MC and
SPOS.B7 REF will be set.

If there are faults during homing:
} Fault handling: see example 3, Tab. 5/6.

Advertising