B. Parametrising as per FHPP−FPC

B−61

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Following record

PNU

416

1...32

d

uint8

rw

Description

The subsequent positioning record for a positioning record with a chaining
condition = 1.

Value range: 1...31

Record 0

(positioning

410

1

(positioning

record 0) Do not use (Homing)

Record ...

(positioning

410

...

(positioning

record ...) The position record following position record 1...30.

Record 31

(positioning

410

32 (20h)

(positioning

record 31) The record following record 31.

CI

20E5h

01h ... 20h

uint8

rw

Note: Object 20E0h/09h is intended for access via DS402.