B. Parametrising as per FHPP−FPC
B−92
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Local digital output 1 ć function
PNU
1240
ć
ć
uint8
rw
Description
Out1: Use. See section 5.6.10.
CI / DS402
2421h
01h
uint8
rw
Local digital output 1 ć trigger ON
PNU
1241
ć
ć
uint8
rw
Description
Out1: Setting condition. See section 5.6.10.
CI / DS402
2421h
02h
uint8
rw
Local digital output 1 ć trigger OFF
PNU
1242
ć
ć
uint8
rw
Description
Out1: Resetting condition. See section 5.6.10.
CI / DS402
2421h
03h
uint8
rw
Local digital output 1 ć value ON
PNU
1243
ć
ć
int32
rw
Description
Out1: Setting with record number comparison. See section 5.6.10.
CI / DS402
2421h
04h
int32
rw
Local digital output 1 ć value OFF
PNU
1244
ć
ć
int32
rw
Description
Out1: Resetting with record number comparison. See section 5.6.10.
CI / DS402
2421h
05h
int32
rw