Festo Контроллеры двигателя SFC-LAC User Manual

Page 278

Advertising
background image

B. Parametrising as per FHPP−FPC

B−50

Festo GDCP−SFC−LACI−CO−EN en 0812NH

FHPP record number

PNU

400

1...3

Array

uint8

r(w)

Description

Record number 400

1

rw

Record pointer for positioning and teaching.
It is also valid when the drive is not in Record Select mode (e.g. during teach−
ing). For record selection this parameter is transferred in the cyclic I/O data.
Value range: 0 ... 34 (0x00 ... 0x22).
Values:
0 (0x00): Homing (positioning record 0)
1 (0x01): Positioning record 1
2 (0x02): Positioning record 2
...:

Positioning record ...

31 (0x1F): Positioning record 31
32 (0x20): Jog mode
33 (0x21): Direct mode
34 (0x22): FCT positioning record

Active record 400

2

r

The number of the active record. Relevant for record chaining.

Record status byte 400

3

r

Contains FHPP status byte 4 with information on record chaining
(see section 5.5.2).

CI

2033h

01h...03h

uint8

r(w)

Note: The object 2032h is intended for access via DS402.