5. Commissioning

5−69

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Start/stop record

Nominal record
number for output
data

Stop CCON.B1
(STOP)

Acknowledge start
SPOS.B1 (ACK)

Motion Complete
SPOS.B2 (MC)

Actual record
number for input
data

N − 1

N

N + 1

N − 1

N

1

0

1

0

1

0

1

0

1

0

1

2

3

4

6

1

0

1

0

Axis moves
SPOS.B4 (MOV)

Start CPOS.B1
(START)

N + 1

5

1

Requirement: Acknowledge start" = 0

2

Rising edge at START causes the new
record number N to be accepted and
Acknowledge start" to be set.

3

As soon as Acknowledge start" is
recognised by the PLC, START may be
set to 0 again.

4

The controller reacts with a falling
edge at Acknowledge start".

5

As soon as Acknowledge start" is
recognised by the PLC, the next record
number may be started.

6

A currently running positioning task
can be stopped with STOP.

Fig. 5/4:

Sequence diagram for start/stop record