6 drive functions, 1 homing, Drive functions – Festo Контроллеры двигателя SFC-LAC User Manual

Page 164: Homing

Advertising
background image

5. Commissioning

5−62

Festo GDCP−SFC−LACI−CO−EN en 0812NH

5.6

Drive functions

5.6.1

Homing

When the device is switched on, homing must be carried out
before a positioning task can be executed.

The drive homes against a stop or a reference switch. A stop
is reached when there is an increase in the motor current at
the same time as the drive shaft comes to a stop. As the drive
must not position continuously against the stop, it must move
at least 1 mm into the stroke range again (offset axis zero
point).

Sequence:

1. Search for the reference point in accordance with the

configured method.

2. Move from reference point to axis zero point (offset axis

zero point).

3. Set at axis zero point:

Actual position = 0 ć project zero point offset (i.e. −PZ).

Advertising