Overview of cables and plugs – Festo Контроллеры двигателя SFC-LAC User Manual

Page 57

Advertising
background image

3. Installation

3−5

Festo GDCP−SFC−LACI−CO−EN en 0812NH

If unused plug connectors are touched, there is a danger that
damage may occur to the SFC−LACI or to other parts of the
system as a result of ESD (electrostatic discharge). Place proĆ
tective caps on unused terminal connections in order to preĆ
vent such discharges.

Overview of cables and plugs

Connection

Cable/plug

Type

1

Parameterising interface

Programming cable

KDI−MC−M8−SUB−9−2,5

2

Controller interface

Fieldbus plug

FBS−SUB−9−BU−2x5POL−B

Fieldbus adapter

FBA−2−M12−5POL

3

Power supply

Power supply cable

KPWR−MC−1−SUB−15HC−...

5

Local digital I/Os

Connecting cable

KM8−M8−... or NEBU−M8−...

6

Motor connection

Motor cable

NEBM−T1G6−T1G6−...

Encoder cable

NEBM−T1G12−T1G12−...

Tab. 3/2: Overview of cables and plugs (accessories)

For complying with the IP protection class: Tighten the union
nuts/locking screws on the plugs by hand; seal unused M8
connections with type ISK−M8 protective caps (accessories).

Observe the tightening torques specified in the documen−
tation for the cables and plugs used.

Festo plugs which comply with protection class IP20:
ć screw terminal adapter type FBA−1−SL−5POL,
ć field bus plug FBS−SUB−9−WS−CO−K.