Direct mode: force mode – Festo Контроллеры двигателя SFC-LAC User Manual

Page 298

Advertising
background image

B. Parametrising as per FHPP−FPC

B−70

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Direct mode: Force mode

Torque/force slope (change of force)

PNU

550

ć

uint32

r

Description

Speed with which the force changes

CI / DS402

6087h

00h

uint32

r

Force target window

PNU

552

ć

uint16

rw

Description

Target window of the force: this is the amount by which the actual force may
differ from the setpoint force in order to be interpreted as still being in the tarĆ
get window. The width of the window is twice the value transferred, with the
target position in the centre of the window.
The value is specified in 1/1000 of the nominal value (6076h / PNU 1036).
Value range: 0...65535. Default: 100

CI / DS402

60F6h

0

3h

uint16

rw

Force damping time

PNU

553

ć

uint16

rw

Description

Damping time of the force: if the actual force has been in the target window this
amount of time, the Motion complete" bit will be set in the status word. Value
range: 0...30000 ms. Default: 100 ms.

CI / DS402

60F6h

0

4h

uint16

rw

Advertising