Festo Контроллеры двигателя SFC-LAC User Manual

Page 324

Advertising
background image

B. Parametrising as per FHPP−FPC

B−96

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Limit switch polarity

PNU

1300

ć

ć

int16

rw

Description

Limit switch type: 0 = no limit switch, 1 = N/C contact, 2 = N/O contact

CI / DS402

6510h

11h

int16

rw

Limit switch selector

PNU

1301

ć

ć

int16

rw

Description

Input for limit switch.
0 none
1 IN0 = limit switch negative

IN1 = limit switch positive

2 IN0 = limit switch positive

IN1 = limit switch negative

3 IN0 = limit switch negative

IN2 = limit switch positive

4 IN0 = limit switch positive

IN2 = limit switch negative

5 IN1 = limit switch negative

IN2 = limit switch positive

6 IN1 = limit switch positive

IN2 = limit switch negative

CI / DS402

6510h

12h

int16

rw

Homing switch selector

PNU

1302

ć

ć

int16

rw

Description

Input for reference switch: 0 = none, 1 = IN0, 2 = IN1, 3 = IN2

CI / DS402

6510h

13h

int16

rw

Homing switch polarity

PNU

1303

ć

ć

int16

rw

Description

Reference switch type: 0 = N/C contact, 1 = N/O contact

CI / DS402

6510h

14h

int16

rw

Advertising