B. Parametrising as per FHPP−FPC
B−96
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Limit switch polarity
PNU
1300
ć
ć
int16
rw
Description
Limit switch type: 0 = no limit switch, 1 = N/C contact, 2 = N/O contact
CI / DS402
6510h
11h
int16
rw
Limit switch selector
PNU
1301
ć
ć
int16
rw
Description
Input for limit switch.
0 none
1 IN0 = limit switch negative
IN1 = limit switch positive
2 IN0 = limit switch positive
IN1 = limit switch negative
3 IN0 = limit switch negative
IN2 = limit switch positive
4 IN0 = limit switch positive
IN2 = limit switch negative
5 IN1 = limit switch negative
IN2 = limit switch positive
6 IN1 = limit switch positive
IN2 = limit switch negative
CI / DS402
6510h
12h
int16
rw
Homing switch selector
PNU
1302
ć
ć
int16
rw
Description
Input for reference switch: 0 = none, 1 = IN0, 2 = IN1, 3 = IN2
CI / DS402
6510h
13h
int16
rw
Homing switch polarity
PNU
1303
ć
ć
int16
rw
Description
Reference switch type: 0 = N/C contact, 1 = N/O contact
CI / DS402
6510h
14h
int16
rw