Parameter for homing – Festo Контроллеры двигателя SFC-LAC User Manual

Page 305

Advertising
background image

B. Parametrising as per FHPP−FPC

B−77

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Parameter for homing

Offset axis zero point

PNU

1010

ć

int32

rw

Description

Offset of the axis zero point AZ to the reference point REF in [increments]
(= distance from reference point). Factory settings: see chapter 5.2.5.
The drive is no longer referenced after the axis zero point has been modified.

CI / DS402

607Ch

00h

int32

rw

Homing method

PNU

1011

ć

uint8

rw

Description

Homing method.
Values

Function

1 (0x01):

Search for limit switch in negative direction with index search

2 (0x02):

Search for limit switch in positive direction with index search

7 (0x07):

Search for reference switch in positive direction with index search

11 (0x0B):

Search for reference switch in negative direction with index search

−18 (0xEE): Search for stop in positive direction
−17 (0xEF): Search for stop in negative direction
The drive is no longer referenced after the homing method has been modified.

CI / DS402

6098h

00h

uint8

rw

Homing velocities

PNU

1012

1...2

int32

rw

Description

Speeds during homing

Search REF

(search for REF)

1012

1

(search for REF)

Speed when searching for the reference point REF in [inc/s]

Search AZ

(search for AZ)

1012

2

(search for AZ)

Speed of travel to the axis zero point AZ in [inc/s]

CI / DS402

6099h

01h...02h

int32

rw

Advertising