B−80

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Target position window

PNU

1022

ć

uint32

rw

Description

Tolerance window in increments [inc]
Amount by which the current position may deviate from the target position, in
order that it may still be regarded as being within the target window. The width
of the window is twice the value transferred, with the target position in the
centre of the window. Value range: 0 ... Stroke Default: 102 Inc

CI / DS402

6067h

00h

uint32

rw

Direct mode position window time

PNU

1023

ć

uint16

rw

Description

Damping time (= adjustment time) in direct mode in milliseconds [ms]
If the actual position has been in the target position window this amount
of time, the bit Target reached" will be set in the status word (= Motion
complete).
Value range: 1 ... 60000 ms. Default: 10 ms.
See. PNU 415 (record−specific damping times in record selection) and 6068h
(damping time of the active record).

CI / DS402

20E6h

22h

uint16