5. Commissioning

5−46

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Status byte 2 (SPOS)

Bit

EN

Description

B0
HALT

Halt

= 0: Hold is active
= 1: Hold is not active, axis can be moved

B1
ACK

Acknowledge
Start

= 0: Ready for start (reference, jog)
= 1: Start carried out

B2
MC

Motion
Complete

= 0: Positioning job active
= 1: Positioning job completed, where applicable with error
Note: MC is set after device is switched on (status Drive blocked")

B3
TEACH

Acknowledge
Teach /
Sampling

Depending on the setting in PNU 354:
Ĉ PNU 354 = 0:

Display of the teach status

SPOS.B3 = 0: Ready for teaching
SPOS.B3 = 1: Teaching carried out, actual value is transferred

Ĉ PNU 354 = 1:

Display of the sampling status

SPOS.B3 = 0: No edge.
SPOS.B3 = 1: An edge has appeared. New position value available.

For position sampling: see section 5.6.12

B4
MOV

Axis is

Moving

= 0: Speed of the axis < limit value
= 1: Speed of the axis >= limit value

B5
DEV

Deviation
Warning

= 0: No following error
= 1: Following error active

B6
STILL

Stand

still

warning

= 0: After MC, axis remains in tolerance window
= 1: After MC, axis remains outside tolerance window

B7
REF

Axis is
Referenced

= 0: Drive is not referenced (homing run must be carried out)
= 1: Drive is referenced