B.3.8 project data, B.3.8, Project data – Festo Контроллеры двигателя SFC-LAC User Manual

Page 291: B−63, B.3.8 project data general project data

Advertising
background image

B. Parametrising as per FHPP−FPC

B−63

Festo GDCP−SFC−LACI−CO−EN en 0812NH

B.3.8

Project data

General project data

Project zero point (offset project zero point)

PNU

500

ć

int32

rw

Description

Offset of the project zero point PZ to the axis zero point AZ.
Reference point for target positions with absolute positioning
(compare PNU 401 and 404).

CI / DS402

21F4h

00h

int32

rw

Software end positions

PNU

501

1...2

int32

rw

Description

Software end positions in increments. Plausibility rule: Min. limit

Ţ Max. limit

Factory settings: see section 5.2.6.

Lower limit

(lower limit value)

501

1

(lower limit value)

Lower software end position: offset to axis zero point

Upper limit

(upper limit value)

501

2

(upper limit value)

Upper software end position: offset to axis zero point

CI / DS402

607Bh

01h...02h

int32

rw