B. Parametrising as per FHPP−FPC
B−63
Festo GDCP−SFC−LACI−CO−EN en 0812NH
B.3.8
Project data
General project data
Project zero point (offset project zero point)
PNU
500
ć
int32
rw
Description
Offset of the project zero point PZ to the axis zero point AZ.
Reference point for target positions with absolute positioning
(compare PNU 401 and 404).
CI / DS402
21F4h
00h
int32
rw
Software end positions
PNU
501
1...2
int32
rw
Description
Software end positions in increments. Plausibility rule: Min. limit
Ţ Max. limit
Factory settings: see section 5.2.6.
Lower limit
(lower limit value)
501
1
(lower limit value)
Lower software end position: offset to axis zero point
Upper limit
(upper limit value)
501
2
(upper limit value)
Upper software end position: offset to axis zero point
CI / DS402
607Bh
01h...02h
int32
rw