2 the menu system, The menu system, 2 the menu system status display and main menu – Festo Контроллеры двигателя SFC-LAC User Manual

Page 88

Advertising
background image

4. The control panel (only type SFC−LACI−...−H2−...)

4−6

Festo GDCP−SFC−LACI−CO−EN en 0812NH

4.2

The menu system

Status display and main menu

When the logic voltage is switched on, the SFC−LACI carries
out an internal check.

During the first commissioning or when the EEPROM is deĆ
leted, the fault message CAN−BUS INIT NO PARAMETER
ERROR" will appear, as the CAN bus parameters are not
parameterised (see section 5.2.1).

In the case of recommissioning (i.e. if the CANbus parameters
have already been completely parameterised), the display
briefly shows the Festo logo and then changes to the status
display.

The

status display shows the following information:

ć

The type designation of the SFC−LACI

ć

The type of connected drive

ć

The position of the drive x

a

= .... (still without significance

when unit is switched on)

ć

The current setting of the device control
(HMI = Human Machine Interface)

The

main menu is accessed from the status display using the

<Menu> key. The currently active key function is displayed in
the lower lines of the LCD display.

CAN–BUS INIT NO
PARAMETER ERROR

Diagnostic <menu>

Config <Enter>

SFC–LACI...
D...
Xa = 0.00 mm

HMI:off
<Menu>

}

Diagnostic
Positioning
Settings
V

ESC <Menu>

<––>

OK <Enter>

}

HMI control
LCD adjustment

v

ESC <Menu>

<––>

OK <Enter>

Advertising