B. Parametrising as per FHPP−FPC

B−25

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Name

CI

FHPP

Name

SI

PNU (SDO)

Axis data electric drives 1 Ĉ control parameters

Quick stop option code

1019 (23FBh)

ć

605Ah

HALT option code

1020 (23FCh)

ć

605Dh

Fault reaction / STOP option code

1021 (23FDh)

ć

605Eh

Target position window

1022 (23FEh)

ć

6067h

Position window time direct

1023 (23FFh)

ć

20E6/22h

Position control parameter set

1024 (2400h)

18...21d

60FBh

Motor data

1025 (2401h)

1, 3

6410h

Drive data

1026 (2402h)

1...7

6510h

I

2

t Value

1027 (2403h)

ć

6410/04h

Max phase current

1028 (2404h)

ć

6410/05h

Quick stop deceleration

1029 (2405h)

ć

6085h

Axis data electric drives 1 Ĉ electronic type plate

Motor type

1030 (2406h)

ć

6402h

Max. current

1034 (240Ah)

ć

6073h

Motor rated current

1035 (240Bh)

ć

6075h

Motor rated torque

1036 (240Ch)

ć

6076h

Axis data electric drives 1 ć standstill monitoring

Position demand value

1040 (2410h)

ć

6062h

Position actual value

1041 (2411h)

ć

6064h

Standstill position window

1042 (2412h)

ć

2040h

Standstill timeout

1043 (2413h)

ć

2041h