B. Parametrising as per FHPP−FPC

B−88

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Commutation status

PNU

1056

ć

uint8

r

Description

State of the commutation point search
0x00: No commutation (default)
0x01: Commutation point search active
0x10: Commutation point successfully found
0xFE: Fault in commutation (POSITION PLAUSIBILITY ERROR)
0xFF: Fault in commutation (COMMUTATION POINT ERROR)

CI / DS402

2050h

00h

uint8

r

Position record power consumption

PNU

1057

ć

uint32

r

Description

Power consumption in [W] during last positioning record.

CI / DS402

6410h

17h

uint32

r

Positioning time

PNU

1058

ć

uint32

r

Description

Duration of the last positioning motion in [ms].

CI / DS402

6410h

18h

uint32

r

Actual current

PNU

1059

ć

int32

r

Description

Actual current in [mA]

CI / DS402

6410h

19h

int32

r