Festo Контроллеры двигателя SFC-LAC User Manual

Page 246

Advertising
background image

B. Parametrising as per FHPP−FPC

B−18

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Step 4

Write record number 1 with target position 0x1234 (decimal
4660 increments):
PNU 404, subindex 2 ć Modify parameter value, array, double
word: ReqID 8 (0x8) with value 0x00001234.

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Reserved

Sub−index ReqID/ResID + PNU

Parameter value

Output
data

0x00

0x02

0x

81

0x

94

0x

00

0x

00

0x

12

0x

34

Input data

0x00

0x02

0x

81

0x

94

0x

00

0x

00

0x

12

0x

34

Step 5

After receiving the input data with ResID 0x8 send output data
with ReqID = 0x0 and wait for input data with ResID = 0x0:

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Reserved

Sub−index ReqID/ResID + PNU

Parameter value

Output
data

0x00

0x02

0x

01

0x94

0x00

0x00

0x12

0x34

Input data

0x00

0x02

0x

01

0x94

0x00

0x00

0x12

0x34

Step 6

Write record number 1 with speed 0x7743 (decimal 30531
increments/s):
PNU 406, subindex 2 ć Modify parameter value, array, double
word: ReqID 8 (0x8) with value 0x00007743.

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Reserved

Sub−index ReqID/ResID + PNU

Parameter value

Output
data

0x00

0x02

0x

81

0x

96

0x

00

0x

00

0x

77

0x

43

Input data

0x00

0x02

0x

81

0x

96

0x

00

0x

00

0x

77

0x

43

Step 7

After receiving the input data with ResID 0x8 send output data
with ReqID = 0x0 and wait for input data with ResID = 0x0:

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Reserved

Sub−index ReqID/ResID + PNU

Parameter value

Output
data

0x00

0x02

0x

01

0x94

0x00

0x00

0x77

0x43

Input data

0x00

0x02

0x

01

0x94

0x00

0x00

0x77

0x43