Festo Контроллеры двигателя SFC-LAC User Manual
Page 266
Advertising
B. Parametrising as per FHPP−FPC
B−38
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Fault number
PNU
201
1...16
d
uint16
r
Description
Fault number saved in the diagnostic memory, serves for identifying the fault.
Fault numbers with descriptions: see section 6.3.
Event ... 201
...
see PNU 200.
CI / DS402
20C9h
01h...10h
uint16
r
Time stamp
PNU
202
1...16
d
uint32
r
Description
Time point of the diagnostic event since device was switched on, in the time
unit as per PNU 204/2.
Event ... 202
...
see PNU 200.
CI / DS402
20CAh
01h...10h
uint32
r
Additional information
PNU
203
1...16
d
0...15
uint32
r
Description
Number of movement cycles at the time a fault comes or goes. See PNU 305.
Event ... 202
...
...
see PNU 200.
CI
20CBh
01h...10h
uint32
r
Advertising