4 [positioning] menu, Positioning] menu – Festo Контроллеры двигателя SFC-LAC User Manual
Page 93
![background image](/manuals/464473/93/background.png)
4. The control panel (only type SFC−LACI−...−H2−...)
4−11
Festo GDCP−SFC−LACI−CO−EN en 0812NH
4.4
[Positioning] menu
Starting a homing run or a positioning run
Warning
Electric axes move with high force and at high speed. ColliĆ
sions may cause injury.
·
Make sure that nobody can place his/her hand in the
positioning range of the moveable mass and that there
are no objects in its path.
Note
·
Before starting homing, make sure that:
Ĉ The positioning system is set up and wired
completely, and is supplied with power.
Ĉ The parameterising is completed.
·
Only start a positioning run after:
Ĉ The reference system has been defined by homing.
Ĉ You have checked that the software end positions are
far enough away from the mechanical end positions /
fixed stops (at least 1 mm).
Note
Please note that positioning records with speed v = 0 or
invalid target positions (−> error TARGET POSITION OUT