Festo Контроллеры двигателя SFC-LAC User Manual

Page 165

Advertising
background image

5. Commissioning

5−63

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Overview of parameters involved (see also section B.3.9)

Parameters involved

Description

FCT

PNU

CI

Offset axis zero point

x

1010

607Ch

Homing method

x

1011

6098h

Homing speeds

x

1012

6099h

Homing required

ć

1014

23F6h

Maximum homing current

x

1015

23F7h

Start (FHPP)

CPOS.B2 = positive edge: start homing

Feedback (FHPP)

SPOS.B1 = positive edge: acknowledge start
SPOS.B7 = drive is referenced

Condition

Device control by PLC/fieldbus; controller in the Operation enabled"
status; no jogging command is present

Tab. 5/11: Parameters involved in homing

Homing methods

1)

Hex

Dec

Description

01h

1

Search for limit switch in negative direction with index search

02h

2

Search for limit switch in positive direction with index search

07h

7

Search for reference switch in positive direction with index search

0Bh

11

Search for reference switch in negative direction with index search

EFh

−17

Search for stop in a negative direction. The point found is the reference
position. As the axis must not stand still at the stop, the offset axis zero
point must be

š 0.

EEh

−18

Search for stop in a positive direction. The point found is the reference
position. As the axis must not stand still at the stop, the offset axis zero
point must be

š 0.

1)

For a detailed description of the homing methods, see section 1.1.6.

Tab. 5/12: Overview of homing methods