B.3.3 representation of the parameter entries, B.3.3, Representation of the parameter entries – Festo Контроллеры двигателя SFC-LAC User Manual
Page 257: B−29
![background image](/manuals/464473/257/background.png)
B. Parametrising as per FHPP−FPC
B−29
Festo GDCP−SFC−LACI−CO−EN en 0812NH
B.3.3
Representation of the parameter entries
Encoder resolution
PNU
1001
1...2
Array
uint32
rw
Description
Encoder resolution in increments / revolutions
The encoder resolution is fixed and cannot be modified by the user.
The calculated value is derived from the fraction (encoder increments/
motor revolution).
Encoder increments
1001
1
Value range: 0 ... 2
32
−1
Default: 500
Motor revolutions
1001
2
Fixed = 1
CI
608Fh
01h...02h
uint32
rw
1
Name of the parameter
2
Parameter number (PNU)
3
Subindices of parameter, if present
4
Class
5
Variable type
6
Read/write permission: r = read only
w = write only
rw = read and write
7
Description of the parameter
8
If applicable: Explanation of the subindices
9
Relevant CI object (specify DS402": also available via DS402)
Fig. B/1: Representation of the parameter entries
1
2
3
4
5
7
8
6
9