5. Commissioning
5−19
Festo GDCP−SFC−LACI−CO−EN en 0812NH
5.2.6
Teach software end positions
Factory settings
by homing method:
Homing method
Factory settings [mm]
Reference switch (AZ: 0 mm)
SW−limit−neg = 0
SW−limit−pos = (nominal
stroke − 10)
Negative stop (AZ: +1 mm)
SW−limit−neg = 0
SW−limit−pos = nominal stroke
Positive stop (AZ: −1 mm)
SW−limit−neg =
−nominal stroke
SW−limit−pos = 0
If necessary, teach the
software end positions:
1. Select [Settings] [Axis parameter] [SW−limit−neg] or
[SW−limit−pos].
2. Move the drive with the arrow keys.
Note
During operation, the drive must not strike a stop without
shock absorption.
·
Parameterise the software end positions at least 1 mm
from the nearest end stop.
3. Accept the position reached with OK <Enter>. The setting
will then take effect.
4. Save the parameter settings in EEPROM with
[SAVE]. Only
then will the settings be retained even after switching off