Festo Контроллеры двигателя SFC-LAC User Manual

Page 69

Advertising
background image

3. Installation

3−17

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Connection

Pin

Designation

Function

Fieldbus
plug

1)

1

5

1

n.c.

Not connected

ć

2

CAN_L

CAN bus low

A/L

6

9

3

5)

CAN GND

CAN bus reference potential

GND

4

n.c.

Not connected

ć

5

Screened

Capacitive connection to housing

Clamping
strap

6

2)

5)

GND logic

3)

Logic power GND (see Tab. 3/3)

ć

5)

GND bus

4)

Bus interface power supply
reference potential

7

CAN_H

CAN bus high

B/H

8

n.c.

Not connected

ć

9

2)

n.c.

3)

Not connected

V+

24 V bus

4)

Power supply to the bus interface

ć

Screening/housĆ
ing

Connection to (FE) functional
earth

Clamping
strap

1)

Pin assignment on fieldbus plug type FBS−SUB−9−BU−2x5POL−B from Festo

2) Depending on parameterisation CAN Voltage Supply" (see section 5.2.1) or [CAN Volt.Supply]

on control panel (see section 4.5.6, [CO parameters] ).

3) Internal supply of the fieldbus node (default): CAN bus (pins 2, 3, 7) referred to logic voltage of

the SFC−LACI.

·

Do not connect pins 6 and 9.

4) External supply of the fieldbus node: CAN bus (pins 2, 3, 7) referred to external power supply

(permits electrically isolated bus connection).

·

Pin 6 and pin 9 must be supplied with 24 V.

5) Pin 3 and pin 6 are connected internally with each other in the SFC−LACI−CO.

Tab. 3/8: I/F" terminal (control terminal) on the SFC−LACI−...−CO