Festo Контроллеры двигателя SFC-LAC User Manual
Page 280
Advertising
![background image](/manuals/464473/280/background.png)
B. Parametrising as per FHPP−FPC
B−52
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Record control byte 2
PNU
402
1...32
d
Array
uint8
rw
Description
For record selection: Step enabling condition for chained records
(see section 5.6.5).
Values:
Bit 0:
= 0 No record chaining
= 1 Record chaining
Bit7:
= 0 Record chaining is not locked out;
= 1 Record chaining is locked out
Record 0
(positioning
402
1
(positioning
record 0) Do not use (Homing)
Record 1
(positioning
402
2
(positioning
record 1) Record control byte 2 Positioning record 1
Record ...
(positioning
402
...
(positioning
record ...) Record control byte 2 Positioning record 2 ... 30
Record 31
(positioning
402
32
(positioning
record 31) Record control byte 2 Positioning record 31
CI
20EBh
01h ... 20h
uint8
rw
Note: Not used with DS402.
Advertising